NEC UNIVERGE NEAX 2000 IPS Phone Systems Go Back Back to #PrePage#
NEC UNIVERGE NEAX 2000 IPS
As a full-featured IP-based communications system, the NEC UNIVERGE NEAX 2000 IPS supports a maximum of 952 IP stations, 512 TDM stations and a combined total of 980 stations. It provides pure VoIP peer-to-peer connections across corporate local and wide area networks. It offers the utmost flexibility by providing a choice of time division switching, pure peer-to-peer IP connectivity or a combination of both, all in one system. It provides a comprehensive cost effective solution for the small to medium sized business, hotel property or the enterprise network environment.
Find NEC UNIVERGE NEAX 2000 IPS Phone Systems dealers nearest you!
 
NEC UNIVERGE NEAX 2000 IPS Phone System
 

NEC UNIVERGE NEAX 2000 IPS
NEC UNIVERGE NEAX 2000 IPS Benefits:
#ShuffleList(BenefitsList)#

NEC UNIVERGE NEAX 2000 IPS
NEC UNIVERGE NEAX 2000 IPS Features:
#ShuffleList(FeaturesList)#

NEC UNIVERGE NEAX 2000 IPS Specifications:
Transmission Characteristics:
Cross Talk Attenuation: More than 70 dB at 1000 Hz
Idle Circuit Noise: Less than -65 dBmp
Leakage Resistance: More than 20,000 ohms
Return Loss: More than 15 dB (300 ~ 3,400 Hz)
Longitudinal Balance Trunk Side: Better than 58 dB
Insertion Loss (relative to 1KHz-10 dBm)
    Station-to-Station: Typical 6 dB
    Station-to-Trunk: Typical 0.5 dB
    Trunk-to-Trunk: Typical 0.5 dB at 0 dB PAD control
PCM Characteristics:
    Line Rate: 1.544 Mbps
    u-Law Law Meets North America TI-D4 Standards
Line Impedance:
    Station: 600 ohms
    Trunk: 600 or 900 ohms

Rotary Dial Pulse:

(1) Receiving Conditions
Dial Speed: 9 ~ 11 pulses per second (pps)
Break Ratio: 55 ~ 77% (10 pps)
Minimum Inter-digital Pause: 192 ms
Switch Hook Flash Detection: 310 ~ 1610 ms a.

(2) Sending Conditions
Dial Speed: 10 pps (±0.8 pps)
Break Ratio: 67 ±3%
Minimum Inter-digit Pause: 800 ms
DTMF Signaling

(1) Receiving Conditions (Measured at Receiver Input)
Signal Duration: More than 40 ms
Inter-digital Pause: More than 40 ms
Signal Level: 0 ~ -25 dBm

(2) Sending Conditions
Signal Duration: More than 64 ms
Inter-digit Pause: More than 64 ms
Signal Level:
Low Frequency: -10 dBm
High Frequency: - 9 dBm


DTMF Frequencies:
  1209Hz 1336Hz 1477Hz
697Hz 1 2 3
770Hz 4 5 6
852Hz 7 8 9
941Hz * 0 #


Audible Tones:
TONE FREQUENCY INTERRUPTION
Dial Tone (DT) 350 Hz mixed with 440 Hz Continuous
Special Dial Tone (SDT) 350 Hz mixed with 440 Hz 0.125 sec. ON, 0.125 sec. OFF
Busy Tone (BT) 480 Hz mixed with 620 Hz 0.5 sec. ON, 0.5 sec. OFF
Reorder Tone (ROT) 480 Hz mixed with 620 Hz 2.5 sec. ON, 0.25 sec. OFF
Howler Tone (HWT) 2,400 Hz interrupted by 16 Hz Continuous
Service Set Tone (SST) 350 Hz mixed with 440 Hz Continuous
Ring Back Tone (RBT) 440 Hz mixed with 480 Hz 1 sec. ON, 3 sec. OFF
Hold Tone (HDT) 480 Hz mixed with 620 Hz 0.25 sec. ON, 0.25 sec. OFF
0.25 sec. ON, 1.25 sec. OFF
Second Dial Tone 440 Hz mixed with 480 Hz 0.25 sec. ON, 0.25 sec. OFF
0.25 sec. ON, 1.25 sec. OFF
Call Waiting Ringback Tone 440 Hz mixed with 480 Hz 1 sec. ON, 1 sec. OFF
Message Waiting Indication Tone 350 Hz mixed with 440 Hz 0.125 sec. ON, 0.125 sec. OFF


Ringing Signal:
Frequency: 20 Hz (Nominal)
Signal Voltage: 75 Vrms (Nominal)
Interruption: (1) 2 sec. ON, 4 sec. OFF (external calls)
(2) 1 sec. ON, 2 sec. OFF (internal calls)
Distinctive ringing is available for trunk routes and class of service options.


Heat Dissipation:
PIM NO. MAX. AC POWER CONSUMPTION (W/H)* MAX. BTU (BTU/H)
1 360 1226
2 720 2452
3 1080 3678
4 1440 4904
5 1800 6130
6 2160 7356
7 2520 8582
8 2880 9808
Note: 1 W/H = 3.4056 BTU

VARSearch currently features NEC UNIVERGE NEAX 2000 IPS dealers from the following states:

#TheStateName#